More info
Table of Contents
1 -
AS 7240.12-2007 Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam
4 -
PREFACE
5 -
CONTENTS
7 -
Introduction
9 -
1 Scope
9 -
2 Normative references
10 -
3 Terms and definitions
11 -
4 General requirements
11 -
4.1 Compliance
11 -
4.2 Individual alarm indication
11 -
4.3 Connection of ancillary devices
11 -
4.4 Monitoring of detachable detectors and connections
11 -
4.5 Manufacturers adjustments
11 -
4.6 On-site adjustment of response threshold value
12 -
4.7 Protection of optical components
12 -
4.8 Limit of compensation
12 -
4.9 Marking
12 -
4.10 Data
13 -
4.11 Requirements for software controlled detectors
14 -
4.12 Fault signalling
14 -
5 Test methods
14 -
5.1 General
16 -
5.2 Reproducibility
17 -
5.3 Repeatability
18 -
5.4 Directional dependence
19 -
5.5 Variation of supply parameters
19 -
5.6 Rapid changes in attenuation
20 -
5.7 Slow changes in attenuation
20 -
5.8 Optical path length dependence
21 -
5.9 Fire sensitivity
23 -
5.10 Stray light
24 -
5.11 Dry heat (operational)
25 -
5.12 Cold (operational)
26 -
5.13 Damp heat, steady state (operational)
27 -
5.14 Damp heat, steady state (endurance)
27 -
5.15 Vibration, sinusoidal (endurance)
28 -
5.16 Electromagnetic compatibility (EMC), immunity tests (operational)
29 -
5.17 Sulfur dioxide, SO2, corrosion (endurance)
30 -
5.18 Impact (operational)
31 -
6 Test report
32 -
Annex A (informative) Compensation for detector drift
37 -
Annex B (normative) Bench for response threshold value measurements
39 -
Annex C (normative) Fire test room
41 -
Annex D (normative) Smouldering pyrolysis wood fire (TF2)
43 -
Annex E (normative) Glowing smouldering cotton fire (TF3)
45 -
Annex F (normative) Flaming plastics (polyurethane) fire (TF4)
47 -
Annex G (normative) Flaming liquid (n-heptane) fire (TF5)
48 -
Annex H (normative) Smoke-measuring instruments
51 -
Annex I (normative) Apparatus for stray light
53 -
Annex J (informative) Information concerning the construction of the measuring ionization chamber
Abstract
Specifies requirements, test methods and performance criteria for line type smoke detectors utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection systems installed in buildings.
General Product Information
Published
|
|
Document Type
|
Standard |
Status
|
Current |
Publisher
|
Standards Australia
|
Pages
|
|
ISBN
|
|
Committee
|
FP-002 |
Under Revision
|
|
Supersedes
|
|
Superseded By
|
|