New Reduced price! AS/NZS 3499:2006 (R2016) View larger

AS/NZS 3499:2006 (R2016)

M00002712

New product

AS/NZS 3499:2006 (R2016)

Water supply - Flexible hose assemblies

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

Abstract

Specifies requirements for flexible hose assemblies for use with both heated and cold water supplies with a maximum heated water temperature of 90 Degrees Celsius, used for applications aboveground, accessible and not submerged. Nominal sizes range up to DN 20, a maximum length of 2 m and with a working pressure not exceeding 1.4 MPa at 20 Degrees Celsius.
RECONFIRMATION NOTICE
Technical Committee WS-001 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 3 September 2015.
Approved for reconfirmation in New Zealand on behalf of the Standards Council of New Zealand on 4 November 2016.
The following are represented on Technical Committee WS-001:
Association of Accredited Certification Bodies
Australian Industry Group
Building Officials Institute of New Zealand
CSIRO
Gas Technical Regulators Committee
Housing Industry Association
National Association of Testing Authorities Australia
Plastics Industry Pipe Association of Australia
Plastics New Zealand
Plumbing Distributors Association of New Zealand
Plumbing Products Industry Group
Queensland Brassware Association
The Institute of Plumbing Australia
Water Services Association of Australia

Scope

This Standard specifies requirements for flexible hose assemblies for use with both heated water and cold-water supplies with a maximum heated water temperature of 90°C used for applications aboveground, accessible and not submerged. Nominal sizes range up to DN 20, a maximum length of 2 m and with a working pressure not exceeding 1.4 MPa at 20Degrees Celsius.
NOTE: Certification under the Plumbing Code of Australia is mandatary in Australia but not in New Zealand.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 23/12/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 23/12/2016
Committee WS-001
Under Revision
  • DR 08127 CP
  • DR 09002 CP
Supersedes
  • DR 06164
  • AS/NZS 3499:1997