New Reduced price! AS 4567-2005 (R2017) View larger

AS 4567-2005 (R2017)

M00003167

New product

AS 4567-2005 (R2017)

Twin wall metal flues - Gas appliances

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Abstract

Provides manufacturers, designers, regulatory authorities, testing laboratories and similar organizations with uniform minimum requirements for the safety, performance and use of twin wall metal flues. These requirements cover twin wall flue and components, excluding flue cowls (refer AS 4566), used for flueing gas appliances with a maximum flue gas temperature of 270°C.

RECONFIRMATION NOTICE
Technical Committee AG-006 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 06 August 2017.
The following are represented on Technical Committee AG-006:
Access Canberra
Association of Accredited Certification Bodies
Association of Hydraulic Services Consultants Australia
Australian Building Codes Board
Caravan Industry Association of Australia
Department of Natural Resources and Mines, QLD
Energy Networks Australia
Gas Appliance Manufacturers Association of Australia
Gas Energy Australia
Gas Technical Regulators Committee
Gas Utilisation Institute, New Zealand
LPG Association of New Zealand
Master Plumbers and Mechanical Services Association of Australia (Victorian)
Master Plumbers, Gasfitters and Drainlayers New Zealand
Standards New Zealand
The Australian Gas Association
Victorian Building Authority
Worksafe New Zealand

Scope

These requirements cover twin wall flue and components, excluding flue cowls (refer AS 4566), used for flueing gas appliances with a maximum flue gas temperature of 270°C.
Flue approved in accordance with these requirements is not suitable for installation where it is inaccessible and subject to continuous condensation.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 29/08/2017.
This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 29/08/2017
Committee AG-006
Supersedes
  • AG 605-1994