New Reduced price! AS 1284.1-2004 View larger

AS 1284.1-2004

M00003312

New product

AS 1284.1-2004

Electricity metering General purpose induction watthour meters

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS 1284.1-2004 ELECTRICITY METERING - GENERAL PURPOSE INDUCTION WATTHOUR METERS</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>SECTION 1 SCOPE AND GENERAL</text>
<bookmark index='4'>
<pageno>6</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>1.2 APPLICATION</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>1.3 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='7'>
<pageno>6</pageno>
<text>1.4 DEFINITIONS</text>
<bookmark index='8'>
<pageno>6</pageno>
<text>1.4.1 Definitions related to the meter</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>1.4.2 Definitions related to components</text>
</bookmark>
<bookmark index='10'>
<pageno>8</pageno>
<text>1.4.3 Characteristic terms</text>
</bookmark>
<bookmark index='11'>
<pageno>9</pageno>
<text>1.4.4 Rated values</text>
</bookmark>
<bookmark index='12'>
<pageno>9</pageno>
<text>1.4.5 Reference conditions</text>
</bookmark>
<bookmark index='13'>
<pageno>9</pageno>
<text>1.4.6 Tests</text>
</bookmark>
</bookmark>
<bookmark index='14'>
<pageno>9</pageno>
<text>1.5 CONDITIONS FOR OPERATION IN SERVICE</text>
</bookmark>
</bookmark>
<bookmark index='15'>
<pageno>10</pageno>
<text>SECTION 2 CONSTRUCTIONAL REQUIREMENTS</text>
<bookmark index='16'>
<pageno>10</pageno>
<text>2.1 GENERAL</text>
</bookmark>
<bookmark index='17'>
<pageno>10</pageno>
<text>2.2 CASE AND TERMINAL COVER</text>
<bookmark index='18'>
<pageno>10</pageno>
<text>2.2.1 Mechanical strength</text>
</bookmark>
<bookmark index='19'>
<pageno>10</pageno>
<text>2.2.2 Ignitability and combustion propagation</text>
</bookmark>
<bookmark index='20'>
<pageno>10</pageno>
<text>2.2.3 Entry of objects, dust and moisture</text>
</bookmark>
<bookmark index='21'>
<pageno>12</pageno>
<text>2.2.4 Visibility of internal parts</text>
</bookmark>
<bookmark index='22'>
<pageno>12</pageno>
<text>2.2.5 Fixing screws (bottom-connected meter)</text>
</bookmark>
</bookmark>
<bookmark index='23'>
<pageno>12</pageno>
<text>2.3 DIMENSIONS</text>
</bookmark>
<bookmark index='24'>
<pageno>13</pageno>
<text>2.4 SECURITY SEALING</text>
</bookmark>
<bookmark index='25'>
<pageno>13</pageno>
<text>2.5 TERMINATIONS (BOTTOM-CONNECTED METERS)</text>
<bookmark index='26'>
<pageno>13</pageno>
<text>2.5.1 Terminals</text>
</bookmark>
<bookmark index='27'>
<pageno>13</pageno>
<text>2.5.2 Clearance and creepage distances</text>
</bookmark>
<bookmark index='28'>
<pageno>13</pageno>
<text>2.5.3 Protection against short-circuit</text>
</bookmark>
</bookmark>
<bookmark index='29'>
<pageno>13</pageno>
<text>2.6 DISCONNECTING DEVICES</text>
</bookmark>
<bookmark index='30'>
<pageno>14</pageno>
<text>2.7 REGISTER</text>
<bookmark index='31'>
<pageno>14</pageno>
<text>2.7.1 General</text>
</bookmark>
<bookmark index='32'>
<pageno>14</pageno>
<text>2.7.2 Multi-rate register</text>
</bookmark>
</bookmark>
<bookmark index='33'>
<pageno>14</pageno>
<text>2.8 ROTOR</text>
<bookmark index='34'>
<pageno>14</pageno>
<text>2.8.1 Magnetic flotation</text>
</bookmark>
<bookmark index='35'>
<pageno>14</pageno>
<text>2.8.2 Disc clearances</text>
</bookmark>
<bookmark index='36'>
<pageno>15</pageno>
<text>2.8.3 Direction of rotation</text>
</bookmark>
<bookmark index='37'>
<pageno>15</pageno>
<text>2.8.4 Disc markings</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='38'>
<pageno>16</pageno>
<text>SECTION 3 ELECTRICAL REQUIREMENTS</text>
<bookmark index='39'>
<pageno>16</pageno>
<text>3.1 STANDARD VALUES</text>
</bookmark>
<bookmark index='40'>
<pageno>16</pageno>
<text>3.2 STANDARD VOLTAGE RATINGS</text>
</bookmark>
<bookmark index='41'>
<pageno>16</pageno>
<text>3.3 STANDARD CURRENT RATINGS (Ib&#140;Imax)</text>
</bookmark>
<bookmark index='42'>
<pageno>16</pageno>
<text>3.4 VOLTAGE AND CURRENT CIRCUIT PARAMETERS</text>
<bookmark index='43'>
<pageno>16</pageno>
<text>3.4.1 Burden of voltage circuit intended for operation from a voltage transformer</text>
</bookmark>
<bookmark index='44'>
<pageno>16</pageno>
<text>3.4.2 Burden of current circuit (CT-operated meter)</text>
</bookmark>
<bookmark index='45'>
<pageno>17</pageno>
<text>3.4.3 Power loss in register changeover device</text>
</bookmark>
</bookmark>
<bookmark index='46'>
<pageno>17</pageno>
<text>3.5 TEMPERATURE LIMITS</text>
<bookmark index='47'>
<pageno>17</pageno>
<text>3.5.1 Temperature limits for electrical insulation</text>
</bookmark>
<bookmark index='48'>
<pageno>17</pageno>
<text>3.5.2 Temperature limits for terminals</text>
</bookmark>
<bookmark index='49'>
<pageno>17</pageno>
<text>3.5.3 Test conditions</text>
</bookmark>
</bookmark>
<bookmark index='50'>
<pageno>17</pageno>
<text>3.6 CONNECTION</text>
</bookmark>
<bookmark index='51'>
<pageno>19</pageno>
<text>3.7 DIELECTRIC PROPERTIES</text>
<bookmark index='52'>
<pageno>19</pageno>
<text>3.7.1 General</text>
</bookmark>
<bookmark index='53'>
<pageno>19</pageno>
<text>3.7.2 Insulation of internal parts</text>
</bookmark>
<bookmark index='54'>
<pageno>19</pageno>
<text>3.7.3 Double insulation</text>
</bookmark>
<bookmark index='55'>
<pageno>19</pageno>
<text>3.7.4 Lightning-impulse withstand test</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='56'>
<pageno>21</pageno>
<text>SECTION 4 PERFORMANCE REQUIREMENTS</text>
<bookmark index='57'>
<pageno>21</pageno>
<text>4.1 REFERENCE CONDITIONS</text>
</bookmark>
<bookmark index='58'>
<pageno>21</pageno>
<text>4.2 LIMITS OF ERROR</text>
<bookmark index='59'>
<pageno>21</pageno>
<text>4.2.1 Meter constant</text>
</bookmark>
<bookmark index='60'>
<pageno>21</pageno>
<text>4.2.2 Register test</text>
</bookmark>
<bookmark index='61'>
<pageno>22</pageno>
<text>4.2.3 Load range errors</text>
</bookmark>
<bookmark index='62'>
<pageno>22</pageno>
<text>4.2.4 Interpretation of test results</text>
</bookmark>
</bookmark>
<bookmark index='63'>
<pageno>22</pageno>
<text>4.3 EFFECT OF INFLUENCE QUANTITIES</text>
<bookmark index='64'>
<pageno>22</pageno>
<text>4.3.1 General</text>
</bookmark>
<bookmark index='65'>
<pageno>22</pageno>
<text>4.3.2 Effect of change of ambient temperature</text>
</bookmark>
<bookmark index='66'>
<pageno>23</pageno>
<text>4.3.3 Effect of change of voltage</text>
</bookmark>
<bookmark index='67'>
<pageno>23</pageno>
<text>4.3.4 Effect of change of frequency</text>
</bookmark>
<bookmark index='68'>
<pageno>23</pageno>
<text>4.3.5 Effect of current waveform distortion</text>
</bookmark>
<bookmark index='69'>
<pageno>23</pageno>
<text>4.3.6 Effect of tilt</text>
</bookmark>
<bookmark index='70'>
<pageno>24</pageno>
<text>4.3.7 Effect of current coil self-heating</text>
</bookmark>
<bookmark index='71'>
<pageno>24</pageno>
<text>4.3.8 Effect of external magnetic field</text>
</bookmark>
<bookmark index='72'>
<pageno>24</pageno>
<text>4.3.9 Effect of reversed-phase sequence (three-element meter)</text>
</bookmark>
<bookmark index='73'>
<pageno>24</pageno>
<text>4.3.10 Effect of alternative usage and phase reversal (two-element meter)</text>
</bookmark>
<bookmark index='74'>
<pageno>25</pageno>
<text>4.3.11 Effect of register friction</text>
</bookmark>
<bookmark index='75'>
<pageno>25</pageno>
<text>4.3.12 Effect of short-time overcurrent</text>
</bookmark>
<bookmark index='76'>
<pageno>25</pageno>
<text>4.3.13 Effect of shock</text>
</bookmark>
<bookmark index='77'>
<pageno>26</pageno>
<text>4.3.14 Effect of high temperature</text>
</bookmark>
<bookmark index='78'>
<pageno>27</pageno>
<text>4.3.15 Effect of register changeover device</text>
</bookmark>
</bookmark>
<bookmark index='79'>
<pageno>27</pageno>
<text>4.4 STARTING</text>
</bookmark>
<bookmark index='80'>
<pageno>27</pageno>
<text>4.5 RUNNING WITH NO LOAD</text>
</bookmark>
</bookmark>
<bookmark index='81'>
<pageno>28</pageno>
<text>SECTION 5 MARKING</text>
<bookmark index='82'>
<pageno>28</pageno>
<text>5.1 NAMEPLATE</text>
</bookmark>
<bookmark index='83'>
<pageno>28</pageno>
<text>5.2 DURABILITY OF MARKING</text>
</bookmark>
<bookmark index='84'>
<pageno>28</pageno>
<text>5.3 DIAGRAMS OF CONNECTIONS</text>
</bookmark>
</bookmark>
<bookmark index='85'>
<pageno>29</pageno>
<text>SECTION 6 DETERMINATION OF COMPLIANCE</text>
<bookmark index='86'>
<pageno>29</pageno>
<text>6.1 TYPE TESTS</text>
</bookmark>
<bookmark index='87'>
<pageno>29</pageno>
<text>6.2 ROUTINE TESTS</text>
</bookmark>
</bookmark>
<bookmark index='88'>
<pageno>31</pageno>
<text>APPENDIX A - INFORMATION TO BE SUPPLIED WITH ENQUIRY AND ORDER</text>
</bookmark>
<bookmark index='89'>
<pageno>32</pageno>
<text>APPENDIX B - LIST OF REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='90'>
<pageno>33</pageno>
<text>APPENDIX C - NOISE LEVEL TESTING OF METERS</text>
<bookmark index='91'>
<pageno>33</pageno>
<text>C1 SCOPE</text>
</bookmark>
<bookmark index='92'>
<pageno>33</pageno>
<text>C2 TEST APPARATUS</text>
</bookmark>
<bookmark index='93'>
<pageno>33</pageno>
<text>C3 PROCEDURE</text>
</bookmark>
<bookmark index='94'>
<pageno>33</pageno>
<text>C4 REPORT</text>
</bookmark>
</bookmark>
<bookmark index='95'>
<pageno>34</pageno>
<text>APPENDIX D - METHOD FOR THE DETERMINATION OF THE RESISTANCE OF CERTAIN COMPONENTS TO ULTRAVIOLET LIGHT</text>
<bookmark index='96'>
<pageno>34</pageno>
<text>D1 SCOPE</text>
</bookmark>
<bookmark index='97'>
<pageno>34</pageno>
<text>D2 PRINCIPLE</text>
</bookmark>
<bookmark index='98'>
<pageno>34</pageno>
<text>D3 TEST APPARATUS</text>
</bookmark>
<bookmark index='99'>
<pageno>34</pageno>
<text>D4 PROCEDURE</text>
</bookmark>
<bookmark index='100'>
<pageno>34</pageno>
<text>D5 REPORT</text>
</bookmark>
</bookmark>
<bookmark index='101'>
<pageno>35</pageno>
<text>APPENDIX E - METHOD FOR THE DETERMINATION OF THE EFFECT OF AN EXTERNAL MAGNETIC FIELD</text>
<bookmark index='102'>
<pageno>35</pageno>
<text>E1 SCOPE</text>
</bookmark>
<bookmark index='103'>
<pageno>35</pageno>
<text>E2 PRINCIPLE</text>
</bookmark>
<bookmark index='104'>
<pageno>35</pageno>
<text>E3 TEST APPARATUS</text>
</bookmark>
<bookmark index='105'>
<pageno>35</pageno>
<text>E4 PROCEDURE</text>
<bookmark index='106'>
<pageno>35</pageno>
<text>E4.1 Single-element meter</text>
</bookmark>
<bookmark index='107'>
<pageno>35</pageno>
<text>E4.2 Multi-element meter</text>
</bookmark>
</bookmark>
<bookmark index='108'>
<pageno>36</pageno>
<text>E5 REPORT</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies safety and performance requirements for general purpose single-rate and multi-rate induction watthour meters with terminals arranged for bottom connection or with contact blades arranged for the meter to plug-in to a socket conforming to AS 1284.4.

Scope

This Standard specifies requirements for general purpose single-rate and multi-rate induction watthour meters (hereinafter referred to as ‘meters’) for the measurement of 50 Hz a.c. electrical energy in domestic, industrial or commercial premises.
The Standard specifies terminal arrangements and connections for bottom-connected meters, also contact blade arrangements and connections for single-element single-phase 2-wire plug-in meters by cross-reference to AS 1284.4.
NOTE: This Standard includes guidance to purchasers of meters. Appendix A provides information which should be supplied with enquiry and order to facilitate the specification and purchase of meters.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
Committee EL-011
Supersedes
  • AS 1284.1-1991
  • AS 1284.1-1991
  • DR 97234