New Reduced price! AS ISO 9239.1-2003 (R2016) View larger

AS ISO 9239.1-2003 (R2016)

M00003630

New product

AS ISO 9239.1-2003 (R2016)

Reaction to fire tests for floor coverings Determination of the burning behaviour using a radiant heat source

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

Abstract

Specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames for all types of flooring. Results obtained by this method reflect the performance of the flooring, including any substrate, if used. Includes details of assessing smoke development and information on the precision of the test method.
RECONFIRMATION NOTICE
Technical Committee FP-018 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 18 November 2015.
The following are represented on Technical Committee FP-018:
Australasian Fire and Emergency Service Authorities Council
Australian Building Codes Board
Australian Industry Group
Australian Institute of Building
AWTA Textile Testing
Building Research Association of New Zealand
Bureau of Steel Manufacturers of Australia
CSIRO
Engineers Australia
Fire Protection Association Australia
Fire Protection Association New Zealand
Forest and Wood Products Australia
Insulated Panel Council Australasia
Insulation Australasia
Insurance Council of Australia
Plastics and Chemicals Industries Association
Property Council of Australia
Society of Fire Protection Engineers

Scope

This European Standard specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames. Annex A gives details of assessing the smoke development, when required.
This method is applicable to all types of flooring e.g. textile carpet, cork, wood, rubber and plastics coverings as well as coatings. Results obtained by this method reflect the performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay or other changes of the flooring may affect test results.
This European Standard is applicable to the measurement and description of the properties of floorings in response to heat and flame under controlled laboratory conditions. It should not be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
Information on the precision of the test method is given in annex B.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 27/05/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
Committee FP-018
Supersedes
  • DR 03097 CP