New Reduced price! AS 4816.1-2002 (R2016) View larger

AS 4816.1-2002 (R2016)

M00003973

New product

AS 4816.1-2002 (R2016)

Determination of particle size distribution by gravitational liquid sedimentation methods General principles and guidelines

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

Abstract

Sets out methods for determining the particle size of particulate materials, typically in the size range 0.5 to 100 µm, by gravitational sedimentation in a liquid. This Standard is identical with and has been reproduced from ISO 13317-1:2001.
RECONFIRMATION NOTICE
Technical Committee NT-001 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been
determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the
original date of publication. Users are advised to ensure that they are using the latest
versions of such documents as appropriate, unless advised otherwise in this
Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for
reconfirmation on 9 September 2016.
The following are represented on Technical Committee NT-001:
Accord Australasia
Australasian College of Toxicology & Risk Assessment
Australian Industry Group
Australian Solar Council
Consumers Federation of Australia
CSIRO
Engineers Australia
National Association of Testing Authorities Australia
National Industrial Chemical Notification and Assessment Scheme
National Measurement Institute
Safe Work Australia
Safety Institute of Australia
University of Adelaide

Scope

This part of ISO 13317 covers methods for determining the particle size distributions of particulate materials, typically in the size range 0,5 m to 100 m, by gravitational sedimentation in a liquid.
NOTE: This part of ISO 13317 may involve hazardous materials, operations and equipment. This part of ISO 13317 does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this part of ISO 13317 to establish appropriate safety and health practices and to determine the applicability of the regulatory limitations prior to its use.
The methods of determining the particle size distribution described in this part of ISO 13317 are applicable to slurries or to particulate materials which can be dispersed in liquids. A positive density difference between the discrete and continuous phases is necessary, although gravitational photosedimentation can be used for emulsions where the droplets are less dense than the liquid in which they are dispersed. Particles should not undergo any physical or chemical change in the suspending liquid. The usual precautions need to be taken with hazardous material, and explosion proof analysers are required when examining volatile liquids with a low flash point.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 23/09/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand.
Reconfirmation Notice 23/09/2016
Committee CH-032
Supersedes
  • DR 01250 CP