New Reduced price! AS 62053.22:2018 View larger

AS 62053.22:2018

M00000034

New product

AS 62053.22:2018

Electricity metering equipment (ac) - Particular requirements Static meters for active energy (classes 0.2 S and 0.5 S) (IEC 62053-22:2016 (ED. 1.1) MOD)

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Abstract

This Standard is an adoption with national modifications and has been reproduced from IEC 62053-22:2003 + AMD.1:2016 CSV (ED.1.1), Electricity metering equipment (a.c.)—Particular requirements, Part 22: Static meters for active energy (classes 0,2 S and 0,5 S). This Standard communicates to users, and also provides manufacturers, with the particular requirements for class 0.2 S and 0.5 S active energy static meters intended for use in Australia.

Scope

This part of IEC 62053 applies only to newly manufactured static watt-hour meters of accuracy classes 0,2 S and 0,5 S, for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
It applies only to transformer-operated static watt-hour meters for indoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the meter case, then the relevant standards for these elements also apply.
NOTE IEC 60044-1 describes transformers having a measuring range of 0,01 In to 1,2 In, or of 0,05 In to 1,5 In, or of 0,05 In to 2 In and transformers having a measuring range of 0,01 In to 1,2 In for accuracy classes 0,2 S and 0,5 S. As the measuring ranges of a meter and its associated transformers have to be matched and as only transformers of classes 0,2 S and 0,5 S have the accuracy required to operate the meters of this standard, the measuring range of the meter will be 0,01 In to 1,2 In.
It does not apply to:
- watt-hour meters where the voltage across the connection terminals exceeds 600 V (lineto- line voltage for meters for polyphase systems);
- portable meters and meters for outdoor use;
- data interfaces to the register of the meter;
- reference meters.
The dependability aspect is covered by the documents of the IEC 62059 series.
The safety aspect is covered by IEC 62052-31:2015.
Regarding acceptance tests, see IEC 62058-11:2008 and IEC 62058-31:2008.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Modifies IEC 62053-22 Ed. 1.1.
Committee EL-011
Supersedes
  • DR AS 62053.22-2018
  • AS 62053.22-2005 (R2016)