New Reduced price! AS/NZS 60928:2000 View larger

AS/NZS 60928:2000

M00004211

New product

AS/NZS 60928:2000

Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - General and safety requirements

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

1 -  AS/NZS 60928:2000 AUXILIARIES FOR LAMPS-A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS-GENERAL AND SAFETY...
4 -  PREFACE
5 -  CONTENTS
6 -  INTRODUCTION
7 -  SECTION 1: GENERAL REQUIREMENTS
7 -  1 Scope
7 -  2 Normative references
9 -  3 Definitions
9 -  3.1 ballast
9 -  3.1.1 independent ballast
9 -  3.1.2 built-in ballast
9 -  3.1.3 integral ballast
9 -  3.1.4 A.C. supplied electronic ballast
9 -  3.1.5 controllable ballasts
9 -  3.1.6 maximum value of lamp power (of a controllable ballast)
10 -  3.1.7 minimum value of lamp power (of a controllable ballast)
10 -  3.1.8 a.c./d.c. supplied electronic ballast for maintained emergency lighting
10 -  3.2 supply voltage
10 -  3.3 working voltage
10 -  3.4 maximum allowed peak voltage
10 -  3.5 supply current
10 -  3.6 live part
10 -  3.7 rectifying effect
10 -  3.8 type test
10 -  3.9 type-test sample
11 -  3.10 rated maximum operating temperature of a ballast case.
11 -  3.11 control terminals
11 -  3.12 control signal
11 -  3.13 cathode dummy resistor
11 -  4 General requirements
11 -  5 General notes on tests
12 -  6 Classification
12 -  7 Marking
12 -  7.1 Mandatory markings
13 -  7.2 Information to be provided, if applicable
13 -  7.3 Marking shall be durable and legible
13 -  SECTION 2: SAFETY REQUIREMENTS
13 -  8 Terminals and cords
13 -  8.1 Terminals
14 -  8.2 Flexible cords
14 -  9 Provision for earthing
14 -  9.1 Protective earth (ground).
15 -  9.2 Functional earth (ground).
15 -  9.3 Frame or chassis.
15 -  10 Creepage distances and clearances
16 -  11 Protection against accidental contact with live parts
16 -  12 Protection of associated components
17 -  13 Moisture resistance and insulation
18 -  14 Electric strength
18 -  15 Abnormal conditions
19 -  16 Fault conditions
20 -  16.1 Short circuit across creepage distances and clearances if they are less than the values specified in clause 10, .....
20 -  16.2 Short circuit across or, if applicable, interruption of semi-conductor devices
20 -  16.3 Short circuit across insulation consisting of covering of lacquer, enamel or textile
20 -  16.4 Short circuit across electrolytic capacitors
20 -  16.5
21 -  17 Screws, current-carrying parts and connections
21 -  18 Resistance to heat and fire
22 -  19 Resistance to corrosion
26 -  Annex A - Test to establish whether a conductive part is a live part which may cause an electric shock
27 -  Annex B - Particular requirements for electronic ballasts with means of protection against overheating
27 -  B.1 Scope
27 -  B.2 Definition
27 -  B.3 General requirements
27 -  B.4 General notes on tests
27 -  B.5 Classification
28 -  B.6 Marking
28 -  B.7 Limitation of heating
30 -  Annex C - Particular additional safety requirements for a.c./d.c. supplied electronic ballasts for maintained emergency light
30 -  C.1 Scope
30 -  C.2 The definifions in clause 2 apply together with the following:
32 -  C.3 Marking
32 -  C.4 General statement
32 -  C.5 Starting conditions
32 -  C.6 Operating conditions
32 -  C.7 Supply current
32 -  C.8 Maximum current in any lead to a cathode
32 -  C.9 Lamp operation current waveform
33 -  C.10 Mains transient overvoltages
33 -  C.11 Pulse voltage from central battery systems
33 -  C.12 Tests for abnormal conditions
33 -  C.13 Temperature cycling test and endurance test
34 -  Annex D - Measurement of high-frequency leakage cuurent
35 -  Annex ZZ - Variations to IEC 60928 for application in Australia and New Zealand
35 -  ZZ1 Introduction
35 -  ZZ2 Variations

Abstract

Specifies safety requirements for electronic ballasts for tubular fluorescent lamps for use on a.c. supplies up to 1000 V at 50 or 60 Hz with operating frequencies deviating from the supply frequency.

Scope

This standard specifies general and safety requirements for electronic ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with tubular fluorescent lamps as specified in IEC 60081 and other tubular fluorescent lamps for high-frequency operation.
Particular requirements for electronic ballasts with means of protection against overheating are given in annex B.
Particular requirements for a.c./d.c. supplied electronic ballasts for maintained emergency lighting are given in annex C.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-041
Supersedes
  • AS 3134-1992
  • DR 99296
Superseded By
  • AS/NZS 61347.2.3:2004