New Reduced price! AS 4538.2-2000 (R2013) View larger

AS 4538.2-2000 (R2013)

M00004232

New product

AS 4538.2-2000 (R2013)

Guide to the sampling of alumina Preparation of samples

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

1 -  AS 4538.2-2000 GUIDE TO SAMPLING OF ALUMINA - PREPARATION OF SAMPLES
4 -  PREFACE
4 -  CONTENTS
5 -  1 SCOPE
5 -  2 REFERENCED DOCUMENTS
5 -  3 DEFINITIONS
5 -  3.1 Increment
5 -  3.2 Sample preparation
5 -  3.3 Sample preparation stage
5 -  4 PRINCIPLE
6 -  5 SAFETY
6 -  6 APPARATUS
6 -  6.1 Rotary splitter
6 -  6.2 Laboratory top-pan balance
6 -  6.3 Laboratory top-pan balance or scales
6 -  6.4 Sample bottles/ containers
6 -  6.5 Dust extraction system
6 -  6.6 Micro rotary splitter
6 -  7 PROCEDURE
6 -  7.1 Sample integrity
7 -  7.2 Mixing sample
7 -  7.3 Division of sample
7 -  7.4 Splitting of sample for analysis
7 -  7.5 Identification of sample
7 -  7.6 Storage
8 -  APPENDIX A - DIAGRAM OF ROTARY SPLITTER
9 -  APPENDIX B - EXAMPLE CALCULATION FOR SAMPLE DIVISION
10 -  APPENDIX C - EXAMPLE OF SAMPLE PREPARATION FLOW CHART

Abstract

Sets out the methods for the sample preparation of smelter-grade alumina. The methods are suitable for dry, free-flowing aluminas.

RECONFIRMATION NOTICE
Technical Committee MN-009 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 9 April 2013.
The following are represented on Technical Committee MN-009:

Australian Institute of Mining and Metallurgy
Australian Aluminium Council
Minerals Council of Australia
Royal Australian Chemical Institute


To view or download a copy of the reconfirmation notice please go to the reconfirmation link near the top of this page.

Scope

This Guide gives methods for the sample preparation of smelter-grade alumina. It covers the reduction of a bulk sample between 2 kg and 20 kg to produce a sample that is suitable for chemical and physical analysis. The reduced sample produced will be representative of the initial bulk sample. The bulk sample is considered to be from one source.
The methods are suitable for dry, free-flowing aluminas.
As the moisture content will influence many physical analyses, the method aims to minimize the exposure of the sample to the atmosphere to avoid water absorption. For preparation of samples for moisture analysis on an ‘as received’ basis, refer to AS 2879.1.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 18-07-2013
Committee MN-009
Supersedes
  • DR 99114