M00004980
New product
Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers Determination of the detective quantum efficiency
Standards Australia
In stock
Warning: Last items in stock!
Availability date: 10/27/2021
Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray systems. It describes a method of determining the detective quantum efficiency of the intensifier. This Standard is identical with and has been reproduced from IEC 1262-5:1994.
RECONFIRMATION NOTICE
Technical Committee HE-003 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 3 March 2016.
Approved for reconfirmation in New Zealand on behalf of the Standards Council of New Zealand on 18 May 2016.
The following are represented on Technical Committee HE-003:
Australasian College of Physical Scientists and Engineers in Medicine
Australian and New Zealand College of Anaesthetists
Australian Chamber of Commerce and Industry
Australian Dental Association
Australian Society of Anaesthetists
Canterbury District Health Board
College of Biomedical Engineering Engineers Australia
Department of Defence (Australian Government)
Engineers Australia
Medical Technology Association of Australia
New Zealand Institute of Healthcare Engineering
Testing Interests (Australia)
Therapeutic Goods Administration
Wairarapa District Health Board
Waitemata District Health Board
Worksafe New Zealand
This International Standard applies to ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS for medical use, as components of diagnostic X-RAY EQUIPMENT. This International Standard describes a method of
determining the DETECTIVE QUANTUM EFFICIENCY (DQE) of X-RAY IMAGE INTENSIFIERS by analysis of
the single gamma-ray photon scintillation pulse-height spectrum. The method of this standard applies only to ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS having output radiance decay rates approximately equal to or faster than that of a P-20 phosphor.
Published | |
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
ProductNote | Reconfirmed 10/06/2016. This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 10/06/2016 |
Pages | |
ISBN | |
Committee | HE-003 |
Supersedes |
|