New Reduced price! AS 4323.2-1995 (R2014) View larger

AS 4323.2-1995 (R2014)

M00005049

New product

AS 4323.2-1995 (R2014)

Stationary source emissions Determination of total particulate matter - Isokinetic manual sampling - Gravimetric method

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Abstract

Sets out an isokinetic manual gravimetric method for the determination of particulate matter emitted from stationary sources such as stacks, ducts or other similar outlets. The method provides a measure of both the concentration and mass flow rate of particulate matter passing through a stack or duct over the sampling period employed.

RECONFIRMATION NOTICE
Technical Committee EV-007 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been determined
that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original
date of publication. Users are advised to ensure that they are using the latest versions of
such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for
reconfirmation on 9 September 2014.
The following are represented on Technical Committee EV-007:
Australian Aluminium Council
Australian Bureau of Meteorology
Australian Chamber of Commerce and Industry
Australian Industry Group
Clean Air Society of Australia and New Zealand
CSIRO Marine and Atmospheric Research
Department of Environment and Conservation, WA
Department of Science, Information Technology, Innovation and the Arts, Qld
Environment Canterbury, New Zealand
Environment Protection Authority, Vic.
Ministry for the Environment, New Zealand
National Association of Testing Authorities Australia
Office of Environment and Heritage, NSW

Scope

This Standard sets out an isokinetic manual gravimetric method for the determination of particulate matter emitted from stationary sources. The method provides a measure of both the concentration and mass flowrate of particulate matter passing through a stack or duct over the sampling period employed.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 14/10/2014.
This standard has been reconfirmed in Australia in 2014 and remains current in New Zealand.
Reconfirmation Notice 14/10/2014
Committee EV-007
Supersedes
  • DR 91218