AS 2867-1986

Farm structures - General requirements for structural design

Standards Australia

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

1 -  AS 2867-1986 FARM STURCTURES - GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN
4 -  PREFACE
4 -  CONTENTS
5 -  SECTION 1. SCOPE AND GENERAL
5 -  1.1 SCOPE
5 -  1.2 NEW MATERIALS OR METHODS
5 -  1.3 REFERENCED DOCUMENTS
5 -  1.4 RESPONSIBILITY FOR DESIGN
5 -  1.5 DEFINITIONS
5 -  1.5.1 Approval
5 -  1.5.2 Engineer
5 -  1.5.3 Farm structure
5 -  1.5.4 Low human occupancy (as applying to farm structures)
5 -  1.5.5 Regulatory Authority
6 -  SECTION 2. GENERAL DESIGN REQUIREMENTS
6 -  2.1 LOADS
6 -  2.1.1 Dead loads
6 -  2.1.2 Live loads
7 -  2.1.3 Loads due to snow
7 -  2.1.4 Loads due to wind
7 -  2.1.5 Loads due to earthquakes
7 -  2.2 DESIGN PROCEDURES
7 -  2.2.1 Design calculations
7 -  2.2.2 Design based on load tests
7 -  2.2.3 Calculations of storage capacity of silos and bins
8 -  APPENDIX A - CALCULATION OF LOADS ON WALLS OF ABOVE-GROUND SILAGE BUNKERS
8 -  A1 GENERAL.
8 -  A2 BASIS FOR CALCULATION
9 -  APPENDIX B - PRESSURE IN GRAIN, GROUND FEED, FRUIT AND VEGETABLE STORAGE
9 -  B1 GENERAL
9 -  B2 NOTATION
9 -  B3 CALCULATION OF GRAIN AND GROUND FEED STORAGE PRESSURES
9 -  B3.1 Coefficients of friction for grain
11 -  B3.2 Pressures in grain and ground feed storage
11 -  B3.3 Pressures in shallow bins
12 -  B3.4 Pressures in bins
12 -  B3.5 Pressures in deep bins
12 -  B3.6 Pressure occurring during centric emptying
12 -  B3.7 Pressure occurring during eccentric emptying
12 -  B4 CALCULATION OF PRESSURES IN BULK FRUIT AND VEGETABLE STORAGE
12 -  B4.1 Shallow bins
12 -  B4.2 Deep bins

Abstract

Specifies requirements for structural design of farm structures with low human occupancy. This Standard covers only minimum requirements for structural design of form structures and does not include other requirements such as fire safety and health.

Scope

This standard specifies requirements for the structural design of farm structures with low human occupancy.

This standard does not include requirements for the structural design of liquid retaining structures used on farms. Health and fire safety requirements are also not included.

NOTES:
1. Reference should be made to the statutory regulations relating to health and safety applicable to the design of farm structures.
2. For requirements of design of farm silos and bins to control insect infestation in grain, see SAA MP46.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote See also HB 867-207.
Committee BD-065
Supersedes
  • DR 84116
Superseded By
  • AS/NZS 1170.0 Supp 1:2002 (R2016)