FOREWORD<br>1 Scope<br>2 Normative references<br>3 Terms and definitions<br>4 Physical background<br>5 Principle of the test methods<br>6 Test procedures<br>7 Sample preparation<br>8 Transfer impedance (short - matched)<br>9 Screening attenuation<br>10 Coupling attenuation<br>11 Coupling transfer function<br>Annex A (informative) - Principle of the triaxial test<br> procedure<br>Annex B (informative) - Triaxial cell<br>Annex C (informative) - Cut off frequencies, higher<br> order modes<br>Annex D (informative) - Coupling transfer function<br>Annex E (informative) - Attenuation versus scattering<br> parameter S[21]<br>Annex F (informative) - Application of a moveable<br> shorting plane<br>Annex G (informative) - Correction in case the receiver<br> input impedance R is higher than the characteristic<br> impedance of the outer circuit Z[2]<br>Bibliography
Defines the procedures for measuring with triaxial cell the transfer impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies and components, e.g. accessories for analogue and digital transmission systems and equipment for communication networks and cabling (in accordance with the scope of IEC technical committee 46).