LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS
British Standards Institution
In stock
Warning: Last items in stock!
Availability date: 11/05/2021
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Terminals
9 Earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Construction
16 Creepage distances and clearances
17 Screws, current-carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
20 No-load output voltage
Annex A (normative) - Test to establish whether a
conductive part is a live part which may cause
an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means of
protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected lamp
controlgear
Annex E (normative) - Use of constant S other than
4500 in tw tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Additional requirements for
built-in magnetic ballasts with double or
reinforced insulation
Annex J (normative) - Schedule of more onerous
requirements
Annex K (informative) - Conformity testing during
manufacture
Annex L (normative) - Particular additional requirements
for controlgears providing SELV
Annex M (informative) - Dielectric strength test voltages
for controlgear intended for the use in impulse
withstand Category III
Annex N (normative) - Requirements for insulation materials
used for double or reinforced insulation
Annex O (normative) - Additional requirements for built-in
electronic controlgear with double
or reinforced insulation
Annex P (normative) - Creepage distances and clearances
and distance through isolation (DTI) for lamp
controlgear which are protected against pollution
by the use of coating or potting
Annex Q (informative) - Example for Up calculation
Annex R (informative) - Concept of creepage distances
and clearances
Annex S (informative) - Examples of controlgear
insulation coordination
Annex T (informative) - Creepage distances and clearances
for controlgear with a higher degree of availability
(impulse withstand category III)
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1000 V at 50 Hz or 60 Hz.
Published | |
Document Type | Standard |
Status | Current |
Publisher | British Standards Institution |
Pages | |
ISBN | |
Committee | CPL/34/3 |
Supersedes |
|