M00019986
New product
NATURAL GAS FUELLING STATIONS - LNG STATIONS FOR FUELLING VEHICLES (ISO 16924:2016)
British Standards Institution
In stock
Warning: Last items in stock!
Availability date: 11/05/2021
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Risk management
6 General design requirements
7 Fuel supply to the fuelling station
8 Storage
9 Pumps and compressors
10 Dispensers
11 Vaporizers and heaters
12 Odorization
13 Pipework
14 Electrical equipment and wiring
15 Instrumentation and control system
16 Emergency shutdown
17 Special configurations
18 Testing and commissioning
19 Operations
20 Inspection and maintenance
Annex A (informative) - Examples of hazardous zones
classification
Annex B (normative) - Separation distances
Annex C (informative) - Example flow diagram of an LNG
fuelling station
Annex D (informative) - Example flow diagram of an LCNG
fuelling station
Annex E (informative) - Example flow diagram of an LNG
and LCNG fuelling station
Annex F (informative) - Process requirements for the effective
cryogenic pump operation
Annex G (informative) - Recommendations for installation of a
centrifugal pump
Annex H (informative) - Recommendations for centrifugal
pump design
Annex I (informative) - Recommendations for installation of a
reciprocating pump
Annex J (informative) - Recommendations on the content of the
cryogenic pump operation instructions
Annex K (informative) - Example flow diagram of a high-pressure
odorizer
Annex L (informative) - LNG identification mark of an LNG
fuelling station
Bibliography
Describes the design, construction, operation, maintenance and inspection of stations for fuelling liquefied natural gas (LNG) to vehicles, including equipment, safety and control devices.
Published | |
Document Type | Standard |
Status | Current |
Publisher | British Standards Institution |
Pages | |
ISBN | |
Committee | GSE/40 |