Table of Contents

Preface
The history and operation of the Canadian Electrical Code, Part I
Metric units
Reference publications
Section 0 - Object, scope, and definitions
Section 2 - General Rules
Section 4 - Conductors
Section 6 - Services and service equipment
Section 8 - Circuit loading and demand factors
Section 10 - Grounding and bonding
Section 12 - Wiring methods
Section 14 - Protection and control
Section 16 - Class 1 and Class 2 circuits
Section 18 - Hazardous locations
Section 20 - Flammable liquid and gas dispensing and service
             stations, garages, bulk storage plants, finishing
             processes, and aircraft hangars
Section 22 - Locations in which corrosive liquids, vapours, or
             excessive moisture are likely to be present
Section 24 - Patient care areas
Section 26 - Installation of electrical equipment
Section 28 - Motors and generators
Section 30 - Installation of lighting equipment
Section 32 - Fire alarm systems, fire pumps, and carbon
             monoxide alarms
Section 34 - Signs and outline lighting
Section 36 - High-voltage installations
Section 38 - Elevators, dumbwaiters, material lifts, escalators,
             moving walks, lifts for persons with physical
             disabilities, and similar equipment
Section 40 - Electric cranes and hoists
Section 42 - Electric welders
Section 44 - Theatre installations
Section 46 - Emergency power supply, unit equipment, exit
             signs, and life safety systems
Section 48 - Motion picture studios, projection rooms, film
             exchanges including film-vaults, and storehouses
             for pyroxylin plastic and nitrocellulose X-ray
             and photographic film
Section 50 - Solar photovoltaic systems
Section 52 - Diagnostic imaging installations
Section 54 - Community antenna distribution and radio and
             television installations
Section 56 - Optical fiber cables
Section 58 - Passenger ropeways and similar equipment
Section 60 - Electrical communication systems
Section 62 - Fixed electric space and surface heating systems
Section 64
Section 66 - Amusement parks, midways, carnivals, film and
             TV sets, TV remote broadcasting locations, and
             travelling shows
Section 68 - Pools, tubs, and spas
Section 70 - Electrical requirements for factory-built relocatable
             structures and non-relocatable structures
Section 72 - Mobile home and recreational vehicle parks
Section 74 - Airport installations
Section 76 - Temporary wiring
Section 78 - Marinas, yacht clubs, marine wharves, structures,
             and fishing harbours
Section 80 - Cathodic protection
Section 82 - Closed-loop and pre-closed-loop power distribution
Section 84 - Interconnection of electric power production sources
Section 86 - Electric vehicle charging systems
Appendix A - Safety standards for electrical equipment, Canadian
             Electrical Code, Part II
Appendix B - Notes on Rules
Appendix C - The Technical Committee on the Canadian Electrical
             Code, Part I - Organization and rules of procedure
Appendix D - Tabulated general information
Appendix E - Dust-free rooms
Appendix F - Recommended installation practice for intrinsically
             safe and non-incendive electrical equipment and wiring
Appendix G - Electrical installations of fire protection systems
Appendix H - Combustible gas detection instruments for use in
             Class I hazardous locations
Appendix I - Interpretations approved since publication of the
             2006 Code
Appendix J - Rules and Notes to Rules for installations using
             the Division system of classification for Class I
             locations
Appendix K - Extract from IEC 60364-1
Index

Abstract

Specifies all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time.

General Product Information

Document Type Standard
Status Current
Publisher Canadian Standards Association