New Reduced price! CSA B140.10 : 2006 View larger

CSA B140.10 : 2006

M00013887

New product

CSA B140.10 : 2006

OIL-FIRED WARM-AIR HEATING APPLIANCES FOR MOBILE HOUSING AND RECREATIONAL VEHICLES

Canadian Standards Association

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

Technical Committee on Oil-Burning Appliance Standards
Preface
Foreword
1 Scope
2 Reference publications and definitions
  2.1 Reference publications
  2.2 Definitions
3 General requirements
  3.1 General
  3.2 Oil burner
  3.3 Electrical features
  3.4 Methods of assembly and shipment
4 Construction requirements
  4.1 General
  4.2 Combustion system
  4.3 Accessibility of parts
  4.4 Location of fuel lines and fuel components
  4.5 Casings and liners
  4.6 Air filters
  4.7 Lubrication
  4.8 Openings into combustion chamber and flue passages
  4.9 Vent system
  4.10 Vent collars
  4.11 Heating surfaces
  4.12 Combustion chambers
       4.12.1 Refractory material
       4.12.2 Metal combustion chambers
       4.12.3 Simulated life test
       4.12.4 Simulated endurance
  4.13 Flue and flame baffles
  4.14 Insulating materials
  4.15 Safety controls
  4.16 Combustion air and dilution air intakes
  4.17 Means of ignition
  4.18 Valves
  4.19 Integral fuel tanks
  4.20 Fuel lines and fittings
  4.21 Fuel oil filter
  4.22 Provision for mounting
  4.23 Flow rate, vaporizing-type burners
  4.24 Oil containment
  4.25 Roof-jacks, flue-gas vents, and connectors
5 Marking
  5.1 General
  5.2 Details required
  5.3 Cautions
6 Instructions
  6.1 General
  6.2 Installation and service manual
  6.3 Operating instructions and homeowner instructions
  6.4 Additional homeowner instructions
7 Normal tests
  7.1 General
       7.1.10 Test enclosure
  7.2 Combustion
       7.2.1 Test requirements
       7.2.2 Test procedures
  7.3 Rated output capacity
       7.3.1 Test requirements
       7.3.2 Test procedures
       7.3.3 Determination of rated output capacity
  7.4 Temperature safety limit control performance
       7.4.1 Test requirements
       7.4.2 Test procedures
  7.5 Continuity of operation
       7.5.1 Test requirements
       7.5.2 Test procedures
  7.6 Operating temperatures
       7.6.1 Test requirements
       7.6.2 Test procedures
  7.7 Motor rating, air-circulating blowers, and fans
       7.7.1 Test requirements
       7.7.2 Test procedures
  7.8 Air filters
  7.9 Cyclic temperature test
       7.9.1 Test requirements
       7.9.2 Test procedure
  7.10 Gas passageway leakage test
       7.10.1 Heat exchanger leakage test
       7.10.2 Carbon dioxide reading
  7.11 Oil containment test
  7.12 Rigidity
       7.12.1 Integral tanks
       7.12.2 Constant-level valves
  7.13 Rain test
8 Abnormal tests
  8.1 General
  8.2 Abnormal temperatures
  8.3 Simulated wind test
       8.3.1 Test requirements
       8.3.2 Test procedure
  8.4 Abnormal voltage
  8.5 Flooding
  8.6 Flooded pot burn-off
  8.7 Power failure
9 Burner tests
  9.1 Vaporizing-type burners
  9.2 Atomizing-type burners
Annexes
A (informative) - Calculation of air-free sample
B (informative) - Marking translations

Abstract

Applies to oil-fired forced warm-air heating appliances for installation in mobile housing and recreational vehicles, irrespective of the heating capacity or the type of burner used.

General Product Information

Document Type Standard
Status Current
Publisher Canadian Standards Association