M00036014
New product
DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - LOWER LAYER PROFILES - FREQUENCY SHIFT KEYING (FSK) PROFILE
International Electrotechnical Committee
In stock
Warning: Last items in stock!
Availability date: 11/06/2021
FOREWORD<br>1 General<br> 1.1 Scope and object<br> 1.2 Normative references<br> 1.3 Acronyms<br>2 The lower layer profile structure<br> 2.1 MAC sublayer<br> 2.2 PLS sublayer<br> 2.3 MAU<br>3 MAC sublayer<br> 3.1 Overview<br> 3.2 Classes of service<br> 3.2.1 Class of service in connection oriented<br> (CO) mode<br> 3.2.2 Class of service in connectionless (CL)<br> mode<br> 3.3 MAC services<br> 3.4 MAC to LLC interfaces<br> 3.4.1 MA_Data.request<br> 3.4.1.1 Function<br> 3.4.1.2 Structure<br> 3.4.1.3 Use<br> 3.4.2 MA_Data.indication<br> 3.4.3.1 Function<br> 3.4.3.2 Structure<br> 3.4.3.3 Use<br> 3.5 MAC to Physical Layer Interfaces<br> 3.6 MAC to Layer Management Interface<br> 3.6.1 Function<br> 3.6.2 Structure<br> 3.6.3 Use<br> 3.7 MAC frame format<br> 3.8 MAC frame<br> 3.9 Elements of the MAC frame<br> 3.9.1 Preamble<br> 3.9.2 Flag<br> 3.9.3 Address<br> 3.9.4 Control<br> 3.9.4.1 Repetition Style 1<br> 3.9.4.2 Repetition Style 2<br> 3.9.5 Repetition<br> 3.9.6 Information<br> 3.9.7 Frame Checking Sequence (FSC)<br> 3.10 MAC invalid frame<br> 3.11 MAC procedures<br> 3.11.1 MACph procedures<br> 3.11.1.1 Transmit a frame<br> 3.11.1.2 Receive a frame<br> 3.11.1.3 Detection of the AC phase delay<br> 3.11.2 MACre procedures<br> 3.11.3 MAC repetition procedures Style 1<br> 3.11.3.1 Service_Class = 1<br> 3.11.3.2 Service_Class = 2<br> 3.11.4 MAC repetition procedures Style 2<br> 3.12 Repetition management<br> 3.13 MAC state transition<br> 3.13.1 State transition table for the operation Style 1<br> 3.13.2 State description<br> 3.13.3 Event descriptions<br> 3.13.4 Actions description<br> 3.13.5 Notation used in the transition table<br>4 PLS sublayer<br> 4.1 PLS service specification<br> 4.1.1 General description of the service<br> 4.1.2 Detailed specification of the service<br> 4.1.2.1 Ph_Data.request<br> 4.1.2.2 Ph_Data.confirm<br> 4.1.2.3 Ph_Data.indication<br> 4.1.2.4 Ph_ZC.indication<br> 4.2 Frame structure and synchronization<br> 4.2.1 Frame structure<br> 4.2.2 Frame synchronization<br> 4.3 MI characteristics<br> 4.3.1 General description of the characteristics<br> 4.3.2 Detailed description of the signals<br> 4.3.2.1 Transmit Data (TD)<br> 4.3.2.2 Receive Data (RD)<br> 4.3.2.3 Mode Control (MC)<br> 4.3.2.4 Bit Clock (BC)<br> 4.3.2.5 Zero Crossing (ZC)<br> 4.4 Description of the procedures<br> 4.4.1 PLS component state descriptions<br> 4.4.2 PLS component event descriptions<br> 4.4.3 PLS component action descriptions<br>5 MAU<br> 5.1 General<br> 5.2 General characteristics<br> 5.2.1 Modulation rate<br> 5.2.2 Frequency range<br> 5.2.3 Optional interchange circuits<br> 5.3 MV modem characteristics<br> 5.3.1 Nominal input-output impedance<br> 5.3.2 Load impedance<br> 5.3.3 Nominal signal output power <br> 5.3.4 Nominal signal frequency band (BN)<br> 5.3.5 Transmission mask<br> 5.3.6 Carrier stabilization<br> 5.3.7 Input sensitivity<br> 5.3.8 Input dynamic range<br> 5.3.9 Bit error rate<br> 5.3.10 Recovered clock jitter<br> 5.4 LV modem characteristics<br> 5.4.1 Frequency bands<br> 5.4.2 Input-output impedance<br> 5.4.3 Load impedance<br> 5.4.4 Transmission mask<br> 5.4.5 Signal frequency stabilization<br> 5.4.6 Input sensitivity<br> 5.4.7 Input dynamic range<br> 5.4.8 Bit error rate<br> 5.4.9 Recovered clock jitter
Covers a lower layer profile including the medium access control (MAC) sublayer, physical signalling (PLS) sublayer and the mains attachment units (MAU) in order to give a contribution for building a set of standards for effective communication on MV and LV network to distribute line carrier (DLC) systems.
Published | |
Document Type | Standard |
Status | Current |
Publisher | International Electrotechnical Committee |
Pages | |
ISBN | |
Committee | TC 57 |