M00036114
New product
FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-6: EXAMINATIONS AND MEASUREMENTS - RETURN LOSS
International Electrotechnical Committee
In stock
Warning: Last items in stock!
Availability date: 11/06/2021
FOREWORD
1 Scope
2 Normative references
3 General description
3.1 Method 1
3.2 Method 2
3.3 Method 3
3.4 Method 4
3.5 Selection of reference measurement method
4 Apparatus and symbols
4.1 Device under test (DUT)
4.2 Method 1: measurements with OCWR
4.2.1 Branching device (BD)
4.2.2 Detector (D[1], D[2] and D[3])
4.2.3 Source (S[1] and S[2])
4.2.4 Temporary joint (TJ)
4.2.5 Termination (T)
4.3 Method 2: measurements with OTDR
4.3.1 Optical time domain reflectometer (OTDR)
4.3.2 Fibre sections (L[1], L[2], and L[3])
4.3.3 Temporary joints (TJ)
4.4 Method 3: measurements with OLCR
4.4.1 Light source (S)
4.4.2 Branching device (BD)
4.4.3 Optical delay line (ODL)
4.4.4 Optical detector (D)
4.4.5 Temporary joint (TJ)
4.4.6 Data processing unit
4.5 Method 4: measurements with an OFDR
4.5.1 RF network analyser
4.5.2 Optical heads - Source (S) and receiver (D)
4.5.3 Optical variable attenuator (A) (optional)
4.5.4 Optical amplifier (OA) (optional)
4.5.5 Isolator (I) (optional)
4.5.6 Branching device (BD)
4.5.7 Temporary joint (TJ)
4.5.8 Computer
5 Procedure
5.1 Launch conditions
5.2 Pre-conditioning
5.3 DUT output port
5.4 Method 1: measurement with OCWR
5.4.1 Definition of the OCWR measurement
5.4.2 Set-up characterization
5.4.3 Measurement procedure
5.4.4 Accuracy considerations
5.5 Method 2: measurement with OTDR
5.5.1 Definition of the OTDR measurement
5.5.2 Evaluation of backscattering coefficient
5.5.3 Measurement procedure
5.5.4 Accuracy considerations
5.6 Method 3: measurement with OLCR
5.6.1 Calibration procedure
5.6.2 Measurement procedure
5.6.3 Accuracy considerations
5.7 Method 4: measurements with OFDR
5.7.1 Calibration procedure
5.7.2 Measurement procedure
5.7.3 Accuracy considerations
6 Details to be specified
6.1 Return loss measurement with OCWR
6.1.1 Reference components
6.1.2 Branching device
6.1.3 Detector
6.1.4 Source
6.1.5 Temporary joint
6.1.6 Termination
6.2 Return loss measurement with OTDR
6.2.1 Reference components
6.2.2 OTDR
6.2.3 L[1], L[2], and L[3]
6.2.4 Fibre
6.3 Return loss measurement with OLCR
6.3.1 Reference components
6.3.2 Source
6.3.3 Branching device (BD)
6.4 Return loss measurement with OFDR
6.4.1 Reference components
6.4.2 Vector network analyser
6.4.3 Branching device
6.4.4 Source
6.4.5 Detector
6.4.6 Optical amplifier (optional)
6.4.7 Isolator (optional)
6.4.8 Calibration
6.5 Measurement procedure
Annex A (informative) Comparison of return loss detectable by
four different methods
Describes procedures for the measurement of the return loss (RL) of a fibre optic device under test (DUT).
Published | |
Document Type | Standard |
Status | Current |
Publisher | International Electrotechnical Committee |
Pages | |
ISBN | |
Committee | TC 86 |