New Reduced price! IEC 60976 : 2.0 View larger

IEC 60976 : 2.0

M00036149

New product

IEC 60976 : 2.0

MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS

International Electrotechnical Committee

More details

In stock

$35.10

-55%

$78.00

More info

Table of Contents

FOREWORD<br>INTRODUCTION<br>1 Scope<br>2 Normative references<br>3 Terms and definitions<br>4 Environmental conditions<br>&nbsp;&nbsp;&nbsp;4.1 General<br>&nbsp;&nbsp;&nbsp;4.2 Transport and storage<br>&nbsp;&nbsp;&nbsp;4.3 Power supply<br>5 General information to the USER<br>&nbsp;&nbsp;&nbsp;5.1 Functional performance characteristics<br>&nbsp;&nbsp;&nbsp;5.2 Available nominal energies and ABSORBED DOSE RATES<br>&nbsp;&nbsp;&nbsp;5.3 Available RADIATION FIELDS<br>&nbsp;&nbsp;&nbsp;5.4 NORMAL TREATMENT DISTANCE<br>&nbsp;&nbsp;&nbsp;5.5 Available WEDGE X-RAY FIELDS<br>&nbsp;&nbsp;&nbsp;5.6 Available flattening FILTERS<br>&nbsp;&nbsp;&nbsp;5.7 Availability<br>&nbsp;&nbsp;&nbsp;5.8 Influencing quantities<br>&nbsp;&nbsp;&nbsp;5.9 Maintenance<br>&nbsp;&nbsp;&nbsp;5.10 Presentation<br>&nbsp;&nbsp;&nbsp;5.11 Dimensions, clearances, within the RADIATION HEAD, and <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;in the region RADIATION HEAD to ISOCENTRE, of BEAM <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;LIMITING DEVICES<br>&nbsp;&nbsp;&nbsp;5.12 IMRT<br>6 Standardized test conditions<br>&nbsp;&nbsp;&nbsp;6.1 General<br>&nbsp;&nbsp;&nbsp;6.2 Angle settings<br>&nbsp;&nbsp;&nbsp;6.3 Properties and positioning of the PHANTOM<br>&nbsp;&nbsp;&nbsp;6.4 Positioning of measuring points<br>&nbsp;&nbsp;&nbsp;6.5 RADIATION DETECTORS<br>&nbsp;&nbsp;&nbsp;6.6 STANDARD MEASUREMENT DEPTHS<br>&nbsp;&nbsp;&nbsp;6.7 RADIATION FIELDS<br>&nbsp;&nbsp;&nbsp;6.8 Adjustments during test<br>&nbsp;&nbsp;&nbsp;6.9 Use of RADIOGRAPHIC FILM or alternative imaging method<br>7 DOSE MONITORING SYSTEM<br>&nbsp;&nbsp;&nbsp;7.1 General<br>&nbsp;&nbsp;&nbsp;7.2 Reproducibility<br>&nbsp;&nbsp;&nbsp;7.3 Proportionality<br>&nbsp;&nbsp;&nbsp;7.4 Dependence on angular positions<br>&nbsp;&nbsp;&nbsp;7.5 Dependence on GANTRY rotation<br>&nbsp;&nbsp;&nbsp;7.6 Dependence on the shape of the RADIATION FIELD<br>&nbsp;&nbsp;&nbsp;7.7 Stability of calibration<br>&nbsp;&nbsp;&nbsp;7.8 Stability in MOVING BEAM RADIOTHERAPY<br>8 Depth ABSORBED DOSE characteristics<br>&nbsp;&nbsp;&nbsp;8.1 X-RADIATION <br>&nbsp;&nbsp;&nbsp;8.2 ELECTRON RADIATION<br>9 Uniformity of RADIATION FIELDS<br>&nbsp;&nbsp;&nbsp;9.1 X-RADIATION<br>&nbsp;&nbsp;&nbsp;9.2 ELECTRON RADIATION<br>&nbsp;&nbsp;&nbsp;9.3 PENUMBRA of RADIATION FIELDS<br>10 Indication of RADIATION FIELDS<br>&nbsp;&nbsp;&nbsp;10.1 X-RADIATION<br>&nbsp;&nbsp;&nbsp;10.2 ELECTRON RADIATION<br>&nbsp;&nbsp;&nbsp;10.3 Geometry and motion speeds of adjustable BLDs for <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;X-RADIATION and ELECTRON RADIATION<br>&nbsp;&nbsp;&nbsp;10.4 Illuminance and PENUMBRA of the LIGHT FIELD<br>11 Indication of the RADIATION BEAM AXIS<br>&nbsp;&nbsp;&nbsp;11.1 General<br>&nbsp;&nbsp;&nbsp;11.2 Indication on entry to the PATIENT<br>&nbsp;&nbsp;&nbsp;11.3 Indication on exit from the PATIENT<br>12 ISOCENTRE<br>&nbsp;&nbsp;&nbsp;12.1 Displacement of the RADIATION BEAM AXIS from the <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;ISOCENTRE<br>&nbsp;&nbsp;&nbsp;12.2 Indication of the ISOCENTRE<br>13 Indication of distance along the RADIATION BEAM AXIS<br>&nbsp;&nbsp;&nbsp;13.1 Indicating device<br>&nbsp;&nbsp;&nbsp;13.2 Additional indicating device for equipment with <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;variable distance between RADIATION SOURCE and <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;ISOCENTRE and for non-isocentric equipment<br>14 Zero position of rotational scales<br>&nbsp;&nbsp;&nbsp;14.1 General<br>&nbsp;&nbsp;&nbsp;14.2 Information to the USER<br>&nbsp;&nbsp;&nbsp;14.3 Tests<br>15 Congruence of opposed RADIATION FIELDS<br>&nbsp;&nbsp;&nbsp;15.1 Information to the USER<br>&nbsp;&nbsp;&nbsp;15.2 Test<br>16 Movements of the PATIENT table<br>&nbsp;&nbsp;&nbsp;16.1 General<br>&nbsp;&nbsp;&nbsp;16.2 Vertical movement of the table<br>&nbsp;&nbsp;&nbsp;16.3 ISOCENTRIC rotation of the table<br>&nbsp;&nbsp;&nbsp;16.4 Parallelism of table rotational axes<br>&nbsp;&nbsp;&nbsp;16.5 Rigidity of the table<br>17 ELECTRONIC IMAGING DEVICE (e.g. EPID)<br>&nbsp;&nbsp;&nbsp;17.1 Information to the USER<br>&nbsp;&nbsp;&nbsp;17.2 Tests<br>Annex A (informative) Format for presentation of functional <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;performances values<br>Index of defined terms

Abstract

Applies to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice.

General Product Information

Document Type Standard
Status Current
Publisher International Electrotechnical Committee
Committee TC 62